Product: AST-HP80 Contact Temperature Measurement Microwave Digestion System
Products
- Chinical Analytical Instruments
- Air Protection Product
- Laboratory And Medical Cryogenic Equipments
- Disinfection And Sterilization Equipments
- Laboratory Incubator
- Drying Oven
- Centrifuge
- Centrifuge
- Laboratory Analysis Equipments
- Laboratory Balance
- Carbon And Sulfur Analyzer
- COD Analyzer
- Water Activity Meter
- Colorimeter
- Cooking Oil Tester
- Densimeter
- Fat Analyzer
- Fiber Analyzer
- Flash Point Tester
- Melting Point Apparatus
- Grain Moisture Meter
- PH Meter
- Titrator
- Portable Chlorophyll Meter
- Leaf Area Meter
- Turbidimeter
- Viscometer
- Soil Nutrient Tester
- Automobile Exhaust Analyzer
- Leakage Tester
- Kjeldahl Apparatus
- Gas Chromatograph
- High Performance Liquid Chromatography
- Plant Photosynthesis Meter
- Plant Analysis Instrument
- Soil Testing Instrument
- Blood Bank Instruments
- Optical Instruments
- Pathology Lab Equipments
- Pharmacy Instruments
- Pre-Processing Of Bio-Samples
- Liquid Processing Instruments
- Molecular Laboratory Equipments
- Microbiological Laboratory Instruments
- Medical Equipments
- Medical Consumables
- Laboratory Solid Processing Equipments
- Other Lab Equipments
- New Products
- Rehabilitation Products
- Neonatal Care Products
Contact Information
- +8613188932181
- info@ansenta.com
Book Appointment
Ansenta would like to establish win-win business cooperation with distributors all over the world.
AST-HP80 Contact Temperature Measurement Microwave Digestion System
Brand:ANSENTA
Product Origin:CHINA
Delivery time:Within 7 days
Supply capacity:Factory Direct Supply
Model:AST-HP80 Contact Temperature Measurement Microwave Digestion System
Introduction:
AST-HP80 contact temperature measurement series closed microwave digestion system as an efficient sample pretreatment equipment, which can provide fast ,safety and clean digestion treatment for users. Also it can expedite the chemical reaction speed and depth of samples under the condition of high temperature and high pressure. So the digestion system will not damage the elements such as highly volatile silver, mercury etc. Widely applied in the chemistry industry, food analysis, environmental monitoring, disease control center, quality supervision and commodity inspection etc.
Download:
AST-HP80 Contact Temperature Measurement Microwave Digestion System
Products Detail
Brief Introduction
AST-HP80 contact temperature measurement series closed microwave digestion system as an efficient sample pretreatment equipment, which can provide fast ,safety and clean digestion treatment for users. Also it can expedite the chemical reaction speed and depth of samples under the condition of high temperature and high pressure. So the digestion system will not damage the elements such as highly volatile silver, mercury etc. Widely applied in the chemistry industry, food analysis, environmental monitoring, disease control center, quality supervision and commodity inspection etc.
Technical Characters
| Model No. | AST-HP80 |
| Power Supply | 220-240 VAC 50/60Hz 16A |
| Microwave Source | 2450MHz, high energy microwave field emission, dual magnetron emission |
| Power | 2000W |
| Max Output Power | 2000W, continuous automatic microwave control |
| Control Way | 7-inch capacity color touch screen, Chinese/English system |
| Microwave Cavity | 67 L large volume 304 stainless steel cavity, multi- layer corrosion- resistant PFA Teflon coating |
| Safety Explosion-proof Door Design | Double-layer metal structure safety door, electronic & mechanical dual control |
| Abnormal State Check | Intelligent judgment of abnormal state inside the cavity to prevent accidents,door state monitoring, the microwave cannot be started unless the door is closed |
| Turntable Design | Coaxial unidirectional rotation, suitable for rotors of various tank positions |
| Pressure Measurement System | Piezoelectric crystal pressure transmission,measuring range: 0- 20MPa(2500psi), platinum accuracy ±0.01 Mpa |
| Temperature Measurement Method | Platinum resistance temperature measurement: temperature range:-40- 350 °C, accuracy ±0.5°C, control accuracy ±0. 1°C |
| Furnace Exhaust System | High-power, corrosion-resistant axial flow fan, high-efficiency air cooling, only 20 minutes from 200°C to 70°C. |
| Working Environment Temperature/humidity | Working temperature: 0-40 degrees, working humidity: 15-85%RH |
| External Dimension | 630X530X630mm |
| Net Weight | 55kgs |
Main Character Of Digestion Tank
| Model No. | AST-HP80 |
| Position | 6-12postion |
| Inner Tank Material | TFM |
| Dissolve The Rotor Frame Structure | Independent frame structure for each digestion tank |
| Reaction Tank Volume | 80ml |
| Work Pressure | 15MPa(2200psi) |
| Maximum Temperature | 200°C |
| HF resistant | Yes |
| Explosion-proof Reaction Tank | Automatic pressure relief with limited pressure, no consumable |
Operating system
1) 7 inch color touch screen
2) Real-time display the components status, and the parameters can be set and modified. 3) Error code database which can display the error code in real-time
4) Display the closed vessel temperature and pressure in real-time
5) Display the temperature, pressure, power curve in real-time
6) Storage the testing process photos which is convenient for future check or error record.
Download:
AST-HP80 Contact Temperature Measurement Microwave Digestion System