نظام AST-HP80 لقياس درجة حرارة التلامس بالموجات الدقيقة AST-HP80

العلامة التجارية:أنسينتا
أصل المنتج:الصين
وقت التسليم:خلال 7 أيام
سعة التوريد:التوريد المباشر من المصنع
الموديل:نظام AST-HP80 لقياس درجة حرارة التلامس بالموجات الدقيقة AST-HP80
مقدمة:
AST-HP80 contact temperature measurement series closed microwave digestion system as an efficient sample pretreatment equipment, which can provide fast ,safety and clean digestion treatment for users. Also it can expedite the chemical reaction speed and depth of samples under the condition of high temperature and high pressure. So the digestion system will not damage the elements such as highly volatile silver, mercury etc. Widely applied in the chemistry industry, food analysis, environmental monitoring, disease control center, quality supervision and commodity inspection etc.
تحميل:
نظام AST-HP80 لقياس درجة حرارة التلامس بالموجات الدقيقة AST-HP80

تفاصيل المنتجات

Brief Introduction
AST-HP80 contact temperature measurement series closed microwave digestion system as an efficient sample pretreatment equipment, which can provide fast ,safety and clean digestion treatment for users. Also it can expedite the chemical reaction speed and depth of samples under the condition of high temperature and high pressure. So the digestion system will not damage the elements such as highly volatile silver, mercury etc. Widely applied in the chemistry industry, food analysis, environmental monitoring, disease control center, quality supervision and commodity inspection etc.

Technical Characters

Model No. AST-HP80
Power Supply 220-240 VAC 50/60Hz 16A
Microwave Source 2450MHz, high energy microwave field emission, dual magnetron emission
Power 2000W
Max Output Power 2000W, continuous automatic microwave control
Control Way 7-inch capacity color touch screen, Chinese/English system
Microwave Cavity 67 L large volume 304 stainless steel cavity,  multi- layer corrosion- resistant PFA Teflon coating
Safety Explosion-proof Door Design Double-layer metal structure safety door, electronic & mechanical dual control
Abnormal State Check Intelligent judgment of abnormal state inside the cavity to prevent accidents,door state monitoring, the microwave cannot be started unless the door is closed
Turntable Design Coaxial unidirectional rotation, suitable for rotors of various tank positions
Pressure Measurement System Piezoelectric   crystal  pressure   transmission,measuring   range:   0- 20MPa(2500psi), platinum accuracy ±0.01 Mpa
Temperature Measurement Method Platinum   resistance temperature   measurement:   temperature   range:-40- 350 °C, accuracy ±0.5°C, control accuracy ±0. 1°C
Furnace Exhaust System High-power, corrosion-resistant axial flow fan, high-efficiency air cooling, only 20 minutes from 200°C to 70°C.
Working Environment Temperature/humidity Working temperature: 0-40 degrees, working humidity: 15-85%RH
External Dimension 630X530X630mm
Net Weight 55kgs

Main Character Of Digestion Tank

Model No. AST-HP80
Position 6-12postion
Inner Tank Material TFM
Dissolve The Rotor Frame Structure Independent frame structure for each digestion tank
Reaction Tank Volume 80ml
Work Pressure 15MPa(2200psi)
Maximum Temperature 200°C
HF resistant Yes
Explosion-proof Reaction Tank Automatic pressure relief with limited pressure, no consumable

Operating system
1) 7 inch color touch screen
2) Real-time display the components status, and the parameters can be set and modified. 3) Error code database which can display the error code in real-time
4) Display the closed vessel temperature and pressure in real-time
5) Display the temperature, pressure, power curve in real-time
6) Storage the testing process photos which is convenient for future check or error record.