{"id":3767,"date":"2026-02-09T00:41:46","date_gmt":"2026-02-09T00:41:46","guid":{"rendered":"https:\/\/www.ansenta.com\/?post_type=product&#038;p=3767"},"modified":"2026-02-09T00:41:46","modified_gmt":"2026-02-09T00:41:46","slug":"ast-hp80-contact-temperature-measurement-microwave-digestion-system","status":"publish","type":"product","link":"https:\/\/www.ansenta.com\/zh\/product\/ast-hp80-contact-temperature-measurement-microwave-digestion-system\/","title":{"rendered":"AST-HP80 Contact Temperature Measurement Microwave Digestion System"},"content":{"rendered":"<p><b>Brief Introduction<\/b><br \/>\nAST-HP80 contact temperature measurement series closed microwave digestion system as an efficient sample pretreatment equipment, which can provide fast ,safety and clean digestion treatment for users. Also it can expedite the chemical reaction speed and depth of samples under the condition of high temperature and high pressure. So the digestion system will not damage the elements such as highly volatile silver, mercury etc. Widely applied in the chemistry industry, food analysis, environmental monitoring, disease control center, quality supervision and commodity inspection etc.<\/p>\n<p><b>Technical Characters<\/b><\/p>\n<table>\n<tbody>\n<tr>\n<td>Model No.<\/td>\n<td>AST-HP80<\/td>\n<\/tr>\n<tr>\n<td>\u7535\u6e90<\/td>\n<td>220-240 VAC 50\/60Hz 16A<\/td>\n<\/tr>\n<tr>\n<td>Microwave Source<\/td>\n<td>2450MHz, high energy microwave field emission, dual magnetron emission<\/td>\n<\/tr>\n<tr>\n<td>Power<\/td>\n<td>2000W<\/td>\n<\/tr>\n<tr>\n<td>Max Output Power<\/td>\n<td>2000W, continuous automatic microwave control<\/td>\n<\/tr>\n<tr>\n<td>Control Way<\/td>\n<td>7-inch capacity color touch screen, Chinese\/English system<\/td>\n<\/tr>\n<tr>\n<td>Microwave Cavity<\/td>\n<td>67 L large volume 304\u00a0stainless steel cavity, \u00a0multi- layer corrosion- resistant\u00a0PFA Teflon coating<\/td>\n<\/tr>\n<tr>\n<td>Safety\u00a0Explosion-proof\u00a0Door Design<\/td>\n<td>Double-layer metal structure safety door, electronic &amp; mechanical dual control<\/td>\n<\/tr>\n<tr>\n<td>Abnormal State Check<\/td>\n<td>Intelligent judgment of abnormal state inside the cavity to prevent accidents,door state monitoring, the microwave cannot be started unless the door is\u00a0closed<\/td>\n<\/tr>\n<tr>\n<td>Turntable Design<\/td>\n<td>Coaxial unidirectional rotation, suitable for rotors of various tank positions<\/td>\n<\/tr>\n<tr>\n<td>Pressure\u00a0Measurement\u00a0System<\/td>\n<td>Piezoelectric \u00a0\u00a0crystal \u00a0pressure \u00a0\u00a0transmission,measuring \u00a0\u00a0range: \u00a0\u00a00- 20MPa(2500psi), platinum accuracy \u00b10.01 Mpa<\/td>\n<\/tr>\n<tr>\n<td>Temperature\u00a0Measurement\u00a0Method<\/td>\n<td>Platinum \u00a0\u00a0resistance\u00a0temperature \u00a0\u00a0measurement: \u00a0\u00a0temperature \u00a0\u00a0range:-40- 350 \u00b0C, accuracy \u00b10.5\u00b0C, control accuracy \u00b10. 1\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Furnace Exhaust System<\/td>\n<td>High-power, corrosion-resistant axial flow fan, high-efficiency air cooling, only\u00a020\u00a0minutes from 200\u00b0C\u00a0to 70\u00b0C.<\/td>\n<\/tr>\n<tr>\n<td>Working\u00a0Environment\u00a0Temperature\/humidity<\/td>\n<td>Working temperature: 0-40 degrees, working humidity: 15-85%RH<\/td>\n<\/tr>\n<tr>\n<td>External Dimension<\/td>\n<td>630X530X630mm<\/td>\n<\/tr>\n<tr>\n<td>\u51c0\u91cd<\/td>\n<td>55kgs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>Main Character Of Digestion Tank<\/b><\/p>\n<table>\n<tbody>\n<tr>\n<td>Model No.<\/td>\n<td>AST-HP80<\/td>\n<\/tr>\n<tr>\n<td>Position<\/td>\n<td>6-12postion<\/td>\n<\/tr>\n<tr>\n<td>Inner Tank Material<\/td>\n<td>TFM<\/td>\n<\/tr>\n<tr>\n<td>Dissolve The Rotor Frame\u00a0Structure<\/td>\n<td>Independent frame structure for each digestion tank<\/td>\n<\/tr>\n<tr>\n<td>Reaction Tank Volume<\/td>\n<td>80ml<\/td>\n<\/tr>\n<tr>\n<td>Work Pressure<\/td>\n<td>15MPa(2200psi)<\/td>\n<\/tr>\n<tr>\n<td>Maximum Temperature<\/td>\n<td>200\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>HF resistant<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Explosion-proof\u00a0Reaction\u00a0Tank<\/td>\n<td>Automatic pressure relief with limited pressure, no consumable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>Operating system<\/b><br \/>\n1) 7 inch color touch screen<br \/>\n2) Real-time display the components status, and the parameters can be set and modified. 3) Error code database which can display the error code in real-time<br \/>\n4) Display the closed vessel temperature and pressure in real-time<br \/>\n5) Display the temperature, pressure, power curve in real-time<br \/>\n6) Storage the testing process photos which is convenient for future check or error record.<\/p>\n<p><span style=\"color: #003300;\"><strong>\u4e0b\u8f7d\uff1a<\/strong><\/span><br \/>\n<a href=\"https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.pdf\">AST-HP80 Contact Temperature Measurement Microwave Digestion System<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p><span style=\"color: #003300;\"><strong>\u54c1\u724c<\/strong><\/span>\u5b89\u68ee\u5854<br \/>\n<span style=\"color: #003300;\"><strong>\u4ea7\u54c1\u4ea7\u5730\uff1a<\/strong><\/span>\u4e2d\u56fd<br \/>\n<span style=\"color: #003300;\"><strong>\u4ea4\u8d27\u65f6\u95f4\uff1a<\/strong><\/span>7 \u5929\u5185<br \/>\n<span style=\"color: #003300;\"><strong>\u4f9b\u5e94\u80fd\u529b\uff1a<\/strong><\/span>\u5de5\u5382\u76f4\u4f9b<br \/>\n<span style=\"color: #003300;\"><strong>\u578b\u53f7<\/strong><\/span>AST-HP80 Contact Temperature Measurement Microwave Digestion System<br \/>\n<span style=\"color: #003300;\"><strong>\u4ecb\u7ecd\uff1a<\/strong><\/span><br \/>\nAST-HP80 contact temperature measurement series closed microwave digestion system as an efficient sample pretreatment equipment, which can provide fast ,safety and clean digestion treatment for users. Also it can expedite the chemical reaction speed and depth of samples under the condition of high temperature and high pressure. So the digestion system will not damage the elements such as highly volatile silver, mercury etc. Widely applied in the chemistry industry, food analysis, environmental monitoring, disease control center, quality supervision and commodity inspection etc.<br \/>\n<span style=\"color: #003300;\"><strong>\u4e0b\u8f7d\uff1a<\/strong><\/span><br \/>\n<a href=\"https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.pdf\">AST-HP80 Contact Temperature Measurement Microwave Digestion System<\/a><\/p>","protected":false},"featured_media":3768,"template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[244],"product_tag":[325,324,326],"class_list":{"0":"post-3767","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-microwave-digester","7":"product_tag-digester-for-lab","8":"product_tag-microwave-digester","9":"product_tag-microwave-digestion-vessel","10":"desktop-align-left","11":"tablet-align-left","12":"mobile-align-left","13":"ast-col-sm-12","14":"ast-article-post","15":"ast-width-md-12","16":"ast-archive-post","17":"ast-product-gallery-layout-horizontal-slider","18":"ast-product-gallery-with-no-image","19":"ast-product-tabs-layout-horizontal","21":"first","22":"instock","23":"shipping-taxable","24":"product-type-simple"},"uagb_featured_image_src":{"full":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.jpg",344,344,false],"thumbnail":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System-150x150.jpg",150,150,true],"medium":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System-300x300.jpg",300,300,true],"medium_large":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.jpg",344,344,false],"large":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.jpg",344,344,false],"1536x1536":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.jpg",344,344,false],"2048x2048":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.jpg",344,344,false],"trp-custom-language-flag":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System-12x12.jpg",12,12,true],"mailpoet_newsletter_max":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.jpg",344,344,false],"woocommerce_thumbnail":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.jpg",344,344,false],"woocommerce_single":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System.jpg",344,344,false],"woocommerce_gallery_thumbnail":["https:\/\/www.ansenta.com\/wp-content\/uploads\/2026\/02\/AST-HP80-Contact-Temperature-Measurement-Microwave-Digestion-System-100x100.jpg",100,100,true]},"uagb_author_info":{"display_name":"jinxing6611@gmail.com","author_link":"https:\/\/www.ansenta.com\/zh\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Brand:ANSENTA Product Origin:CHINA Delivery time:Within 7 days Supply capacity:Factory Direct Supply Model:AST-HP80 Contact Temperature Measurement Microwave Digestion System Introduction: AST-HP80 contact temperature measurement series closed microwave digestion system as an efficient sample pretreatment equipment, which can provide fast ,safety and clean digestion treatment for users. Also it can expedite the chemical reaction speed and depth&hellip;","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.ansenta.com\/zh\/wp-json\/wp\/v2\/product\/3767","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ansenta.com\/zh\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.ansenta.com\/zh\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ansenta.com\/zh\/wp-json\/wp\/v2\/media\/3768"}],"wp:attachment":[{"href":"https:\/\/www.ansenta.com\/zh\/wp-json\/wp\/v2\/media?parent=3767"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.ansenta.com\/zh\/wp-json\/wp\/v2\/product_brand?post=3767"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.ansenta.com\/zh\/wp-json\/wp\/v2\/product_cat?post=3767"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.ansenta.com\/zh\/wp-json\/wp\/v2\/product_tag?post=3767"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}