Товар: Атомно-абсорбционный спектрофотометр-AA320N Plus

Продукция

Контактная информация

Заказать прием

Компания Ansenta хотела бы наладить взаимовыгодное деловое сотрудничество с дистрибьюторами по всему миру.

Атомно-абсорбционный спектрофотометр-AA320N Plus

Бренд:ANSENTA
Происхождение продукта:КИТАЙ
Время доставки:В течение 7 дней
Объем поставок:Прямые поставки с завода
Модель:Атомно-абсорбционный спектрофотометр-AA320N Plus
Скачать:
Атомно-абсорбционный спектрофотометр-AA320N Plus

Подробная информация о продукции

Main Features
Integrated flame and graphite furnace system with quick and easy switching between flame and graphite furnace atomizers.
The optical platform is integrally cast, featuring excellent anti-vibration performance and a more stable optical system, with minimal light loss and high sensitivity.
Equipped with a full-wavelength, high-resolution symmetric aberration-corrected Czerny-Turner monochromator for ultra-accurate wavelength positioning.
4-lamp automatic rotating turret with simultaneous preheating function to optimize operating conditions.
Built-in storage for over 500 sets of data with power-off memory; test methods and results can be retrieved at any time.
Standard configuration with a fully functional workstation software for user-friendly operation (audit trail function available as an option).
Advanced and precise graphite furnace temperature control technology, combined with a self-diagnostic and protective system for equipment faults.

Technical Specifications
Monochromator Type: Czerny-Turner
Grating: 1800 lines/mm
Grating Blaze Wavelength: 250nm
Wavelength Range: 190nm ~ 900nm
Spectral Bandwidth: 0.1 nm, 0.2nm, 0.4nm, 0.7nm, 1.0nm, 2.0nm (automatic switching)
Wavelength Indication Error: ±0.30nm
Wavelength Repeatability: ≤ 0.15nm
Absorbance Range: -0.1 ~ 2.000A
Dynamic Baseline Stability: ≤0.005A/30min (Cu spectral line)
Characteristic Concentration: 0.02μg/mL / 1% (Cu element)
Detection Limit: 0.006μg/mL (Cu element)
Spectral Bandwidth Deviation: ≤0.2nm±0.02nm (0.2nm bandwidth, Cu element)
Measurement Repeatability: ≤0.7% (flame method, Cu element)
Lamp Holder: 4 positions
Main Unit Dimensions: 700mm×630mm×530mm
Net Weight: 80kg

Software
Instrument self-test function
Password setting function
The method establishment module supports the configuration of instrument parameters, calibration curve and slope recalibration parameters, as well as flame atomizer parameters.

Optional Accessories
GA3202 Plus Graphite Furnace System
AS4020 Graphite Furnace Autosampler
AS800 Cooling Water Circulator
Hydride Generator
Hollow Cathode Lamps for various elements

Скачать:
Атомно-абсорбционный спектрофотометр-AA320N Plus